Bertan Precision High Voltage Power Solutions This document in PDF format
  A Spellman High Voltage Company * 800-811-0638 * sales@spellmanhv.com

 Series AR
 Automatic Polarity Reversing DC Output High Voltage Power Supplies
 Manuals for Series AR

Series AR

 

 

 

 

 

 

ARM - 30

  • Up To 30kV Output Available
  •  Automatic Polarity Reversal
  •  Instrument and Modular Designs
  •  Remote Control and Monitoring
  •  PC Interface and Software Available
  •  Custom And OEM Designs Available
  •  Constant Voltage/Current Control
     with Auto Crossover
 

ARB - 30


Output | Input | Performance | Features | Mechanical | Options
Output

Voltage and Current:
0 to ±30kV @ 0 to 400µAdc

Polarity:
User selectable via remote input logic signal compatible with TTL, open collector and relay logic. If polarity reversal is commanded during high voltage operation, the unit will automatically turn off, wait for discharge, reverse polarity and then resume high voltage operation at the new polarity, at the same output voltage magnitude. At 1000 megohm load the polarity reversing time duration will be less than 2 seconds, measured from the time of switching to 90% of final voltage. The time duration is reduced at higher loading (increased output current).

Input

Power:
+24Vdc (+5% / -2%) @ 2Adc maximum (1.5Adc typical).

Performance

Voltage Regulation:
±0.01% of maximum for -2% to +5% input line change.
±0.01% of maximum for 0 to maximum rated output current change.

Current Regulation:
±0.05% of maximum for -2% to +5% input line change.
±0.1% of maximum for 0 to maximum rated output current change.

Ripple:
0.05% peak-to-peak at maximum output.

Temperature Coefficient (0 to 50°C):
100ppm of maximum per °C.

Storage Temperature:
-40°C to +85°C

Stability (after 1/2 hr. warm-up):
0.01% per hour ; 0.02% per 8 hours.

Energy Storage:
Less than 0.35 Joule.

Discharge Time:
The power supply will discharge with a time constant of less than 450 milliseconds. (With 1000 megohm load, discharge to 10% of output in >1 second).

Features

Local Output Voltage and Current Controls:
Two independent multi-turn potentiometers for voltage and current control.

Remote Programming:
Two 0 to +10Vdc programming inputs can be used to independently control the output high voltage and current from 0 to their maximum ratings. Accuracy is ±(0.25% of setting + 0.25% of maximum). The programming input impedance is 10 megohm.

Voltage Monitor:
0 to ±10Vdc for 0 to ±30kV output. The monitor output impedance is 1 kilohms and the accuracy is ±(0.25% of reading +0.25% of maximum).

Current Monitor:
0 to +10Vdc for 0 to 400µA output. The monitor output impedance is 1 kilohms. The accuracy is ±(0.25% of reading +0.5% of maximum).

Interlock:
A remote safety ENABLE input is provided. The remote ENABLE must be connected to COMMON to turn on the high voltage output.

Protection:
Arc and short circuit protection, self-restoring.

Mechanical

Size:
5"W x 3.75"H x 9"L (127 x 95 x 229mm)

Weight:
7lbs (3.2kg)

Mounting:
8-32 blind insert, located at 4 places on the bottom of the unit (127mm x 229mm surface).

High Voltage Connector:
Alden 8101QFP. A mating high voltage connector assembled to three meters of high voltage cable, Bertan P/N B200J118, is provided with each unit.

Input and I/O Connector:
Standard 15 pin "D" type connector provides the functions as listed in the chart below. A mating connector is provided. Connector is located on the same side as the high voltage connector.

PIN # FUNCTION
1 OUTPUT Local control (Jumper Pin 1 to Pin 2)
2 OUTPUT Remote Program (0 to +10 Vdc Input)
3 IOUTPUT Local Control (Jumper Pin 3 to Pin 4)
4 IOUTPUT Remote Program (0 to +10Vdc Input)
5 OUTPUT Monitor (0 to +10Vdc Output)
6 Polarity Control (POS/NEG)
7 COMMON +24Vdc Return
8 +24Vdc Return (COMMON)
9 POS/NEG Indicator (High = +15V, Low = 0)
10 N.C.
11 IMODE / VMODE Indicator (High = +15V, Low = 0)
12 Interlock/ENABLE Logic Input
13 IOUTPUT Monitor (0 to +10Vdc Output)
14 +10Vdc Reference Output
15 +24Vdc Input Power (ARM only)

Options

Bench Top Instruments (Series ARB):
A stand-alone ac-input, bench top instrument version of this supply is available. Calibrated front panel controls and digital meters, as well as remote programming and monitoring are provided. Resolution of front panel voltage reading is 100V; resolution for current is 1µA. AC input voltage range is 100Vac-240Vac, 47-63Hz, universal (no switching required).

Adobe Acrobat Documents

The following documents are available in Adobe Acrobat (PDF) format. The Adobe Acrobat Reader allows you to view, navigate, and print PDF files across all major computor platforms. To get a free reader click on the "Get Acrobat Reader" icon. To view a document click on the title below. To download a document onto your computer hold down the SHIFT key and click on the title (Netscape) or right-click on the title and select "Save Target As ..." (Internet Explorer). Instructions may vary on some browsers and versions.


Top | Home | Products | Contacts | Support | Technical Info | Feedback | News | Site Map
Visa, Mastercard, and American Express accepted
Copyright © Spellman High Voltage 2004. All rights reserved. 
Send comments pertaining to this page to the webmaster