Bertan Precision High Voltage Power Solutions This document in PDF format
  A Spellman High Voltage Company * 800-811-0638 * sales@spellmanhv.com

Series 605C
Compact Precision High Voltage Power Supply Modules

Series 605C
  • Compact Models up to 20kV
  •  High Stability
  •  Low Ripple & Noise
  •  0.001% Regulation
  •  50 PPM Temperature Coefficient
  •  Local & Remote Programming
  •  Voltage & Current Monitoring
  •  Arc & Short Circuit Protected
  •  Custom Models Available
  •  CE Certified

General | Output | Input | Performance | Features | Mechanical | Custom Models
General

The Series 605C is a family of regulated, fixed output polarity, modular high voltage power supplies. They provide exceptional performance and value in many applications including CRTs, spectrometers, detectors, imaging and electron beam applications.

The Series 605C require DC input power, +28V. The units are fully enclosed and designed for system or bench top operation. A wide range of stable output voltages, up to 20kV, is available.

The output voltage is controlled locally by an internal multi-turn potentiometer. Provision for remote analog voltage or resistance programming is included in all models. Analog monitor outputs are also included for remote monitoring of both the high voltage and current outputs. Remote control capability includes a remote ON/OFF logic input.

Output

     MODEL        VOLTAGE     CURRENT   RIPPLE
(pk-pk)
605C-10P,N 0 to 1kV 0 to 9mA 15mV
605C-15P,N  0 to 1.5kV 0 to 6mA 15mV
605C-30P,N 0 to 3kV 0 to 3mA 30mV
605C-50P,N 0 to 5kV  0 to 1.5mA 50mV
 605C-100P,N 0 to 10kV  0 to 750µA 200mV
 605C-150P,N 0 to 15kV 0 to 400µA  450mV
605C-200P,N 0 to 20kV 0 to 250µA  750mV
Polarity:

All models have fixed output polarity, either positive or negative (suffix P or N).

Input

Power:
+28Vdc ±5% @ 0.75 Amperes.

Performance

Line Regulation:
±0.001% of maximum for ±5% input line change.

Load Regulation:
±0.002% of maximum for 0 to maximum-rated output current change.

Ripple:
See chart.

Temperature Coefficient (0 to 50°C):
50ppm of maximum per °C.

Storage Temperature:
-40°C to +85°C

Stability (after ½ hr . warm-up):
0.01% per hour; 0.02% per 8 hours.

Features

Local Control:
Internal multi-turn potentiometer for 0 to maximum output voltage (±0.2%).

Remote Programming:
0 to +5 Volt dc analog input signal proportional to 0 to maximum rated output. Accuracy is ±(0.1% of setting + 0.1% of maximum). The programming input impedance is greater than 10 megohms. Provision is included to configure the unit (by means of an internal jumper) for 0 to -5 Volt analog programming.

Voltage Monitor:
0 to +5 Volts proportional to 0 to maximum output high voltage. Accuracy is ±(0.1% of reading + 0.1% of maximum). The monitor output impedance is 10 kilohms.

Current Monitor:
0 to +5 Volts proportional to 0 to maximum output current. Accuracy is ±(2.0% of reading + 1.0% of maximum). The monitor output impedance is 10 kilohms.

Interlock:
Remote interlock disables (low) and enables (high) the high voltage output. Signal is normally high and supply will default to an "enabled" condition.

Current Limit:
All units provide short circuit current limiting to less than 110% of the maximum rated output current. Supply is self restoring upon removal of cause of limit condition.

Protection:
Short circuit and arc protected; self-restoring.

Mechanical

Size:
5" H x 2.75" W x 4.75" D (127 x 70 x 121mm).

Weight:
3.2 lbs (1.45 kg).

High Voltage Connector:
All models use a Bertan P/N JGA high voltage connector. The mating connector, P/N PGC (Alden 8101) assembled to 1.5 meters of high voltage cable is provided.

Low Voltage I/O Connector:
9 pin Molex connector for remote programming, remote voltage monitoring, remote current monitoring, and remote turn ON/OFF functions. The mating connector and pins are provided.

Custom Models

The Series 605c can be economically and quickly modified to satisfy custom applications. Other output voltage and/or current ratings, custom control features, digital programming, or special mechanical constraints are some of the varied requirements which can be satisfied. Contact Bertan Sales Engineering for a prompt review of your application.

Adobe Acrobat Documents

The following documents are available in Adobe Acrobat (PDF) format. The Adobe Acrobat Reader allows you to view, navigate, and print PDF files across all major computor platforms. To get a free reader click on the "Get Acrobat Reader" icon. To view a document click on the title below. To download a document onto your computer hold down the SHIFT key and click on the title (Netscape) or right-click on the title and select "Save Target As ..." (Internet Explorer). Instructions may vary on some browsers and versions.


Top | Home | Products | Contacts | Support | Technical Info | Feedback | News | Site Map
Visa, Mastercard, and American Express accepted
Copyright © Spellman High Voltage 2004. All rights reserved. 
Send comments pertaining to this page to the webmaster