Series 230
Up to 15W Compact Precision Bench Top
High Voltage Power Supplies

Series 230
  • Up to 30 kV Output Models
  •  Reversible Polarity
  •  Low Ripple & Noise
  •  Short Circuit & Arc Protected
  •  Remote Control & Monitoring
  •  Custom and OEM Designs
  •  Digital Voltage & Current Metering
  •  CE Certified

General | Output | Input | Performance | Features | Mechanical | Options | Custom Models
General

The Series 230 is a family of regulated, compact, precision high voltage power supplies. A wide range of models with high voltage output up to 30kV is available. The output polarity is reversible for all models. Operation is safe and convenient for bench top or system applications.

A single front panel precision dial sets the high voltage output. Automatic current limiting and arc protection assures reliable operation. Remote output voltage and current monitoring, remote output high voltage programming and a high voltage operation interlock are also included.

Output

OUTPUT
 MODEL  VOLTAGE  CURRENT  RIPPLE
(pk-pk)
230-01R 0 to 1kV 0 to 15mA 10mV
230-03R 0 to 3kV 0 to 5mA 30mV
230-05R 0 to 5kV 0 to 3mA 50mV
230-10R 0 to 10kV 0 to 1.5mA 500mV
230-20R 0 to 20kV 0 to 500µA 2V
230-30R 0 to 30kV 0 to 400µA 5V

Polarity:

Polarity reversal is provided on all models. For 1kV through 5kV models, polarity reversal is achieved by a switch accessible at the right side of the unit. For 10kV through 30kV models, polarity reversal is achieved by the reversal of an internal connector. The selected polarity is displayed by a front panel LED indicator.
 
Input

Power:
115 Vac ±10% @ 0.5 Ampere, 50-60Hz.
230 Vac ±10% @ 0.25 Amperes, 50-60Hz.
A 115V/230V switch and 1.0 Ampere fuse are included.

Performance

Line Regulation:
±0.002% of maximum for +10% input line change.

Load Regulation:
0.005% of maximum for 0 to maximum rated output current change.

Temperature Coefficient (0 to 50°C):
100ppm of maximum per °C.

Storage Temperature:
-40°C to +85°C

Stability (after ½ hr warm-up):
0.01% per hour ; 0.02% per 8 hours.

Features

Front Panel Meter:
Front panel 3½ digit LCD meter, switch selectable
for reading either output voltage or current.

METER ACCURACY
 MODEL    VOLTAGE     CURRENT  
230-01R 0.5% + 2V 2% + 20µA
230-03R 0.5% + 20V 2% + 20µA
230-05R 0.5% + 20V 2% + 20µA
230-10R 0.5% + 20V 2% + 2µA
230-20R 0.5% + 200V 2% + 2µA
230-30R 0.5% + 200V 2% + 2µA

Front Panel Controls:
Calibrated front panel 10-turn potentiometer. The resolution of the control is 0.2% of maximum. Accuracy is ±(0.2% of setting + 0.2% of maximum).

High Voltage Programming:
A 0 to +5 Volt programming input can be used to control the output high voltage from 0 to maximum. Accuracy is ±(0.1% of setting + 0.1% of maximum). A rear switch panel selects either front panel or remote control. The programming signal is applied at the rear panel remote I/O connector.

Voltage and Current Monitors:
Two outputs, 0 to +5 Volts proportional to 0 to maximum output voltage and current. Accuracy is ±(0.1% of reading +0.1% of maximum) for the output voltage monitor and is ±(2.0% of reading + 1.0% of maximum) for the output current. The monitor output impedance is 10 kilohms.

Interlock:
Remote interlock disables (low), enables (high) the high voltage output. Signal on interlock pin is normally high and supply will default to an "enabled" condition.

Current Limit:
All units provide short circuit current limiting to less than 120% of the maximum rated output current. A rear panel switch that can select a current limit of 25% of maximum rated output is also provided.

Protection:
Short circuit output current is limited. Arc protected and self-restoring.

Mechanical

Size:
7-5/8" W x 7½" D x 5-1/32" H (194 x 191 x 128mm).

Weight:
10 lbs (4.5 kg).

High Voltage Connector:
Mating high voltage connectors are provided with each unit. For 10kV through 20kV models, a mating connector, assembled to 1.5 meters of high voltage cable, is provided. The Bertan part numbers for the HV output and appropriate mating connectors are as shown in the chart below. P/N PDB is equivalent to MHV type UG-932/U. The 30kV supply is provided with a three meter output cable w/connector attached. Preassembled HV cable for units up to 5kV must be purchased separately.

HV CONNECTOR
MODEL OUTPUT MATING
230-01R JDK PDB
230-03R JDK PDB
230-05R JDK PDB
230-10R JGA PGC-008L151-000
230-20R JGA PGC-008L151-000
230-30R JGS B200J118

Power Input Connector:
3-wire IEC line cord receptacle. Detachable line cord is included.

Low Voltage I/O Connector:
Standard 9 pin "D" type connector for access to remote voltage monitoring, remote current monitoring and remote turn ON/OFF functions. A mating connector is provided.

Custom Models

The Series 230 can be economically and quickly modified to satisfy custom applications. Other output voltage and/or current ratings, custom control features, digital programming, or special mechanical constraints are some of the varied requirements which can be satisfied. Contact Bertan Sales Engineering for a prompt review of your application.

Adobe Acrobat Documents

The following documents are available in Adobe Acrobat (PDF) format. The Adobe Acrobat Reader allows you to view, navigate, and print PDF files across all major computor platforms. To get a free reader click on the "Get Acrobat Reader" icon. To view a document click on the title below. To download a document onto your computer hold down the SHIFT key and click on the title (Netscape) or right-click on the title and select "Save Target As ..." (Internet Explorer). Instructions may vary on some browsers and versions.


Top | Home | Products | Contacts | Support | Technical Info | Feedback | News | Site Map
Visa, Mastercard, and American Express accepted
Copyright © Spellman High Voltage 2004. All rights reserved. 
Send comments pertaining to this page to the webmaster